ASTM E331 00 PDF

The ASTM E (Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure. Imison. John H. Waskow, P.E.. Architectural Testing, Inc. Test Method: ASTM E , Test Method for Water Penetration of Exterior Windows, Curtain Walls. Purchase your copy of ASTM E – 00() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards.

Author: Dusar Yojinn
Country: Norway
Language: English (Spanish)
Genre: Science
Published (Last): 6 August 2009
Pages: 207
PDF File Size: 19.39 Mb
ePub File Size: 14.92 Mb
ISBN: 231-2-96578-867-6
Downloads: 41955
Price: Free* [*Free Regsitration Required]
Uploader: Kir

This test method does not address these issues. ASTM states that the field test may be made at the aetm the window, skylight, curtain wall or door assemblies are initially installed. This specification is for quality assurance testing only. The reviewing of project documents for the building. The main objective of forensic water testing is to identify the leak paths through the simulation of the weather events that produced the reported leakage.

Historical Version s – r331 previous versions of standard. SITC determines what procedure to utilize based on the laboratory testing results. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

ASTM International – Standard References for ASTM E – 00()

This test method does not identify unobservable liquid water which may penetrate into the test specimen. Most generic specifications call for a minimum testing pressure of 6. This allows us to not only properly test fenestrations d331 new construction projects, but also pinpoint the cause of any test failures and provide wstm recommendations to achieve successful testing results.

We provide testing services throughout the United States from our headquarters located in Atlanta, GA. Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset.

Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. ASTM states the field test may also be made after the building is completed and in service to determine whether or not reported leakage problems are due to the failure of the installed assemblies.

Related Posts (10)  CONTRATO COLECTIVO DE TRABALHO IPSS PDF

The evaluation of the design concept to determine if any water resistance performance requirements were specified for the wall.

ASTM E331 – 00(2016)

Link to Active This link will always route to the current Active version of the standard. This standard is utilized for either field quality assurance testing or forensic testing.

BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

The AAMA is the proper test method for field testing of storefronts, curtain walls and sloped glazing for air leakage resistance ashm water penetration resistance performance.

Which would be referred to as quality assurance testing. Building Diagnostics Group, Inc. This field water check method is not intended to test the rated or specified water performance representative of a wind driven rain event.

It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

Give us a call to discuss your next project. Some designs are more sensitive zstm others to this upward moving water. Read more about what our customers have to say Our field consultants are properly trained and knowledgeable of all testing standards. The air-pressure differences acting across a building envelope vary greatly.

Related Posts (10)  6AV6642-0BC01-1AX1 EPUB

This test method exclusively utilizes a uniform static air pressure difference.

The determination of the service history of the building to provide patterns in the observed leakage and visible damage and where to focus our investigation. If you are looking for a reputable second or third-party awtm company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today.

Water Penetration Field Testing

Analyzing the data and establishing a cause and effect relationship between wall characteristics and the observed leakage. The diagnostic field water check is utilized for installed storefronts, curtain walls and sloped glazing systems only.

Referenced Documents purchase separately The documents aatm below are referenced within the subject standard but are not provided as part of the standard. BDG has extensive knowledge of most building systems and w331 in forensic water intrusion investigations.

This differs greatly from the AAMA and AAMA field testing procedures that are intended for evaluating newly installed fenestration products or quality assurance testing.

ASTM E | Water Penetration Testing

ASTM E references the following documents: The calibrated spray apparatus spray-rack system delivers water to the test specimen at a rate of 5. The ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Asm is a testing standard that describes the procedures to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying uniform static pressure to asm sides of the test specimen.

Procedure A is a uniform static air pressure difference. MISSION Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset.